AISC Design Guide 16: Flush and Extended Multiple-Row Moment End-Plate Connections, 2002 Edition

AISC Design Guide 16: Flush and Extended Multiple-Row Moment End-Plate Connections, 2002 Edition
Item #: 330-8162-02
Author: AISC
Publisher: AISC
Manufacturer Item #: 816-02
Format: Paperback
Your Price: $99.95
In Stock


Adhere to the standards set forth in AISC Design Guide 16
Design Guide 16 covers the design of flush and extended multiple row moment end-plate connections. The text includes a review of the uses and classifications of moment end-plate connections, general end-plate connection design procedures, and specific procedures for flush end-plate design, extended end-plate design,and gable frame panel zone design.

AISC Design Guide 16: Flush and Extended Multiple-Row Moment End-Plate Connections, 2002 Edition - Table of Contents:

  • Uses and Classification of Moment End-Plate
    • Connections
    • Introduction
    • Background
    • Design Procedures for Moment End- Plates with Fully Tightened Bolts
    • Design Procedures for Moment End- Plates with Snug Tight Bolts
    • Finite Element Analysis of Moment End-Plates
    • Performance of Moment End-Plate
    • Connections for Seismic Loading
  • Design Procedures
    • Introduction
    • Yield-Line Theory and Mechanics
    • Bolt Force Predictions
    • Moment-Rotation Relationships
    • Design Procedures
    • Design Procedure 1
    • Design Procedure 2
    • Additional Assumptions and Conditions
    • Limit States Check List
  • Flush End-Plate Design
    • Design Equations, Limitations, and Definitions
    • Design Equations
    • Limitations
    • Definitions
    • Design Examples
    • Two-Bolt Flush Unstiffened Moment End-Plate Connection
    • Four-Bolt Flush Unstiffened Moment End-Plate Connection
    • Four-Bolt Flush Stiffened Moment End-Plate Connection (Stiffener Between Bolt Rows)
    • Four-Bolt Flush Stiffened Moment End-Plate Connection (Stiffener Outside Bolt Rows)
  • Extended End-Plate Design
    • Design Equations, Limitations, and Definitions
    • Design Equations
    • Limitations
    • Definitions
    • Design Examples
    • Four-Bolt Extended Unstiffened Moment End-Plate Connection
    • Four-Bolt Extended Stiffened Moment End-Plate Connection
    • Multiple Row 1/2 Extended Unstiffened Moment End-Plate Connection
    • Multiple Row 1/3 Extended Unstiffened Moment End-Plate Connection
    • Multiple Row 1/3 Extended Stiffened Moment End-Plate Connection
  • Gable Frame Panel Zone Design
    • Introduction
    • LRFD Rules and Example Calculations
    • LRFD Rules
    • LRFD Example
    • Allowable Stress Design Rules and Example Calculations
    • Allowable Stress Design Rules
    • ASD Example Calculations
  • REFERENCES
  • APPENDIX A: Nomenclature
  • APPENDIX B: Bolted End-Plate Connection Analysis
  • Flowchart