ACI 530/530.1 - Building Code Requirements & Specifications for
This code covers the design and construction of masonry
structures. It is written in such form that it may be adopted by reference in a
legally adopted building code.
Among the subjects covered are: definitions; contract
documents; quality assurance; materials; placement of embedded items; analysis
and design; strength and serviceability; flexural and axial loads; shear;
details and development of reinforcement; walls; columns; pilasters; beams and
lintels; seismic design requirements; glass unit masonry; and veneers. An
empirical design method applicable to buildings meeting specific location and
construction criteria are also included.
Updates to the 2005 edition include:
- Introduction of AAC (Autoclaved Aerated Concrete) Masonry
- Harmonization of allowable stress and strength design provisions for lap
splices and development lengths
- Revised maximum reinforcement limits for strength design
- Added provisions for confined special boundary elements to strength design
- Introduction of prescriptive requirements for anchored veneer
ACI 530/530.1 - Building Code Requirements & Specifications for Masonry Structures, 2005 - Table of Contents:
** BUILDING CODE 530-05 & COMMENTARY
- GENERAL DESIGN REQUIREMENTS FOR MASONRY
- Scope
- Contract documents and calculations
- Approval of special systems of design or construction
- Standards cited in this code
- Notation
- Definitions
- Loading
- Material properties
- Section properties
- Deflection
- Stack bond masonry
- Corbels
- Details of reinforcement and metal accessories
- Seismic design requirements
- Quality assurance program
- Construction
- ALLOWABLE STRESS DESIGN OF MASONRY
- General
- Unreinforced masonry
- Reinforced masonry
- STRENGTH DESIGN OF MASONRY
- General
- Unreinforced (plain) masonry
- Reinforced masonry
- PRESTRESSED MASONRY
- General
- Design Methods
- Permissible stressed in prestressing tendons
- Axial compression & flexure
- Axial tension
- Shear
- Deflection
- Prestressing tendon anchorages, couplers & end blocks
- Protection of prestressing tendons & accessories
- Development of bonded tendons
- EMPIRICAL DESIGN OF MASONRY
- General
- Height
- Lateral Stability
- Compressive stress requirements
- Lateral support
- Thickness of masonry
- Bond
- Anchorage
- Miscellaneous requirements
- VENEERS
- General
- Anchored veneer
- Adhered veneer
- GLASS UNIT MASONRY
- General
- Panel Size
- Support
- Expansion joints
- Base surface treatment
- Mortar
- Reinforcement
- APPENDIX A - Strength Design of Autoclaved Aerated Concrete (AAC) Masonry,
pg. C-57
- A.1 General
- A.2 Unreinforced (plain) AAC masonry
- A.3 Reinforced AAC masonry
- CONVERSION OF INCH-POUND UNITS TO SI UNITS pg C-65
** 530.1 CONTENTS
- Introduction
- General Responsibilities
- Forms of Contracts
- Conclusion
- References
- Appendix