Construction Book Express     Print Page
PO Box 5196
Janesville, WI 53547-5196

Phone Number: 608-743-8031
Fax Number: 608-743-8037
Toll Free Number: 1-800-253-0541
Toll Free Fax Number: 1-800-647-7233


ACI 530/530.1 - Building Code Requirements & Specifications for Masonry Structures, 2005 CD-ROM

ACI 530/530.1 - Building Code Requirements & Specifications for Masonry Structures, 2005 CD-ROM
Item #: 180-6465-05CD
Author: MSJC
Publisher: ACI
ISBN:53005CD
Format: CD-ROM
Your Price: $115.95
In Stock


The updated 2004 ACI 530/530.1 now available on CD-ROM

ACI 530/530.1 - Building Code Requirements & Specifications for This code covers the design and construction of masonry structures. It is written in such form that it may be adopted by reference in a legally adopted building code.

Among the subjects covered are: definitions; contract documents; quality assurance; materials; placement of embedded items; analysis and design; strength and serviceability; flexural and axial loads; shear; details and development of reinforcement; walls; columns; pilasters; beams and lintels; seismic design requirements; glass unit masonry; and veneers. An empirical design method applicable to buildings meeting specific location and construction criteria are also included.

Updates to the 2005 edition include:

  • Introduction of AAC (Autoclaved Aerated Concrete) Masonry
  • Harmonization of allowable stress and strength design provisions for lap splices and development lengths
  • Revised maximum reinforcement limits for strength design
  • Added provisions for confined special boundary elements to strength design
  • Introduction of prescriptive requirements for anchored veneer

ACI 530/530.1 - Building Code Requirements & Specifications for Masonry Structures, 2005 - Table of Contents:

** BUILDING CODE 530-05 & COMMENTARY

  • GENERAL DESIGN REQUIREMENTS FOR MASONRY
    • Scope
    • Contract documents and calculations
    • Approval of special systems of design or construction
    • Standards cited in this code
    • Notation
    • Definitions
    • Loading
    • Material properties
    • Section properties
    • Deflection
    • Stack bond masonry
    • Corbels
    • Details of reinforcement and metal accessories
    • Seismic design requirements
    • Quality assurance program
    • Construction
  • ALLOWABLE STRESS DESIGN OF MASONRY
    • General
    • Unreinforced masonry
    • Reinforced masonry
  • STRENGTH DESIGN OF MASONRY
    • General
    • Unreinforced (plain) masonry
    • Reinforced masonry
  • PRESTRESSED MASONRY
    • General
    • Design Methods
    • Permissible stressed in prestressing tendons
    • Axial compression & flexure
    • Axial tension
    • Shear
    • Deflection
    • Prestressing tendon anchorages, couplers & end blocks
    • Protection of prestressing tendons & accessories
    • Development of bonded tendons
  • EMPIRICAL DESIGN OF MASONRY
    • General
    • Height
    • Lateral Stability
    • Compressive stress requirements
    • Lateral support
    • Thickness of masonry
    • Bond
    • Anchorage
    • Miscellaneous requirements
  • VENEERS
    • General
    • Anchored veneer
    • Adhered veneer
  • GLASS UNIT MASONRY
    • General
    • Panel Size
    • Support
    • Expansion joints
    • Base surface treatment
    • Mortar
    • Reinforcement
  • APPENDIX A - Strength Design of Autoclaved Aerated Concrete (AAC) Masonry, pg. C-57
    • A.1 General
    • A.2 Unreinforced (plain) AAC masonry
    • A.3 Reinforced AAC masonry
  • CONVERSION OF INCH-POUND UNITS TO SI UNITS pg C-65

    ** 530.1 CONTENTS

  • Introduction
  • General Responsibilities
  • Forms of Contracts
  • Conclusion
  • References
  • Appendix
Close Window